For Johns Manville pipe insulation over metric PP-R, use its PP-R outside-diameter “Best Fit” table rather than converting the pipe’s millimetres directly into inches. In the named bulletin, 50 mm PP-R maps to a 2⅛-inch insulation size and 63 mm maps to 2⅝ inch. Those are the manufacturer’s fit designations for its stated system, not insulation thicknesses or universal sizes for every brand.
This reference helps a mechanical buyer read a metric PP-R pipe schedule against that specific insulation bulletin. It addresses whether the selected section can close around the pipe. Required thermal performance, condensation control and the suitability of the complete insulation product remain separate decisions.
Key Takeaways
- Start with the PP-R pipe’s outside diameter in millimetres.
- Use the named insulation manufacturer’s matching table.
- The recommended fit size is not the insulation wall thickness.
- A direct millimetre-to-inch calculation does not reproduce a product-fit designation.
- Keep the exact insulation product, fit size and required thickness together on the order.

The JM table for metric PP-R
The Johns Manville technical bulletin, dated June 15, 2025, describes its insulation IDs as based on standard US/English pipe sizes and supplies the following metric PP-R mapping for full section closure. Preserve that manufacturer and application scope when using the table.
| PP-R outside diameter | JM recommended “Best Fit” size |
|---|---|
| 20 mm | ½ inch |
| 25 mm | ¾ inch |
| 32 mm | 1 inch |
| 40 mm | 1¼ inch |
| 50 mm | 2⅛ inch |
| 63 mm | 2⅝ inch |
| 75 mm | 3⅛ inch |
| 90 mm | 3⅝ inch |
| 110 mm | 4 inch |
| 125 mm | 4½ inch |
| 160 mm | 6 inch |
| 200 mm | 8 inch |
| 250 mm | 10 inch |
| 315 mm | 12 inch |
The larger rows reproduce the insulation bulletin’s coverage. They are not evidence that IFANULTRA supplies every pipe size listed. Likewise, this is not a substitute for the insulation supplier confirming the exact product and available ordering code.
Why “50 mm” does not become the ordering label by arithmetic
Consider a drawing identifying a 50 mm outside-diameter PP-R run. Its insulation package is to use the JM bulletin. The table returns 2⅛ inch. That is the fit designation to carry into the enquiry for the specified insulation product; it is not a claim that the pipe itself has changed diameter.
A direct unit conversion answers a different question: how many inches equal 50 mm? It does not answer which named insulation section the manufacturer recommends over that pipe. Replacing a product-fit lookup with unit arithmetic can therefore produce a different order even when the arithmetic is correct.
Now change the requirement from JM insulation to another manufacturer’s product. The same PP-R pipe still has the same outside diameter, but this table no longer establishes the new product’s correct ordering size. Obtain that manufacturer’s intended pipe fit or explicit confirmation. Do not carry the JM designation across suppliers as a universal rule.
The public Heating Help discussion “Insulating pipes” contains a buyer’s question about measured cast-iron diameters not matching insulation labels. That is a different pipe material, so its numerical answers are not PP-R recommendations. It illustrates the underlying naming problem; the PP-R-specific answer here comes from the actual JM bulletin.
Keep fit, thickness and scope in separate order fields
| Field | Entry or action | Meaning |
|---|---|---|
| Pipe outside diameter | 50 mm PP-R | The pipe to be covered |
| Manufacturer fit reference | JM bulletin 0102-1; 2⅛ inch | Named fit lookup |
| Insulation product and code | Confirm with the insulation supplier | The actual item being ordered |
| Required insulation thickness | Enter the project’s specified value | A separate thermal-design input |
If thickness is absent, the fit lookup is complete but the insulation order is incomplete. Obtain the project insulation requirement before finalizing the product. If the insulation brand or pipe outside diameter is absent, even the fit lookup remains on hold: identify the pipe and product system first, then use its matching table.
There is no need to guess a thickness to fill that blank. The table contains no temperature, humidity, thermal-conductivity or code-compliance selection. It cannot establish whether the assembled insulation prevents condensation or satisfies an energy requirement. The existing hot-water insulation guide addresses that broader design task; this page is the manufacturer-specific fit reference.
For a pipe enquiry, use the Série PPR Global and provide the actual outside diameter, wall specification and application for an availability check. Ask the insulation supplier to confirm its matching section separately. No JM insulation stock, distribution relationship or supply offer by IFANULTRA is established here.

- Identify the pipe outside diameter and the actual insulation product.
- If the JM bulletin does not apply, obtain the actual supplier fit table or confirmation.
- For the named JM system, read the metric PP-R Best Fit row.
- Record the insulation product code and separately specified thickness.
- If required order fields are missing, hold the order and obtain those inputs; otherwise send the complete enquiry.
Conclusão
Use the pipe OD to enter the named manufacturer’s table, retain its fit designation, and add the separately specified insulation thickness and product code. For JM’s published PP-R mapping, 50 mm returns 2⅛ inch; a different supplier requires its own confirmation. A successful fit lookup resolves one ordering field rather than the entire insulation design.
Frequently Asked Questions
Does 2⅛ inch mean insulation thickness?
No. In this table it is the recommended fit-size designation over 50 mm PP-R. Required insulation thickness is a separate field.
Can this table select foam insulation from another brand?
It does not establish that product’s fit. Use the other manufacturer’s own sizing basis or obtain confirmation for the actual PP-R outside diameter.
Does a listed pipe size prove IFANULTRA supplies it?
No. These rows describe the JM insulation bulletin’s scope. Confirm the particular pipe and insulation products separately.
Author: Justin